• Detailed introduction
  • Features

    1. Fully enclosed metal enclosure, anti-interference
    2. LED displays system status
    3. Equipped with an alarm system, enabling remote alerts
    4. Open-ended design to accommodate future expansion needs
    5. Compact structure with a rational layout
    6. Power failure ensures uninterrupted gas supply
    7. Equipped with an electric heating function to meet various gas requirements.
    8. Suitable for media such as oxygen, air, nitrogen, nitrous oxide, carbon dioxide, and more

     

    Applicable Gases

    Oxygen / Nitrogen / Laughing Gas / Carbon Dioxide, etc.

     

    Left input, right input pressure 0.4–15 MPa
    Outlet pressure 0.3–1.0 MPa (adjustable)
    Nominal Flow Rate >100 m³/h
    Pipe interface ribbing M33×2 (can be manufactured upon request)
    Switch pressure 0.6–1 MPa (adjustable)
    Switching time 3S
    Operating voltage 24VDC
    Operating current 250mA
    Using the residual gas pressure in the steel cylinder <0.8 MPa
    External dimensions 600×500×180